Service
Remediate pipe infrastructure you already have. . . for a lower cost, faster turnaround, and no major disassembly.
Corrosion Inspection
Remove space between words. Remove photo space make all touch each other at the bottom
Basic Services
- Tracing and Identification
- Visual Inspection
- Camera Inspection
Additional Available Services
- NDT gauging (Wall Thickness gauging)
- Samples of Sulfides
- Samples of Manganese
- Samples of corrosive biofouling
- Pipe sent for additional laboratory testing
External Pipe Repair
When pipe system physical condition is in doubt, wall thickness is measured using manual or electronic means to discover the average thickness and general condition. It is recommended that piping inspected having less than 15-20% of original wall thickness are replaced. In instances where isolated pinholes (1.5≤mm) are present within otherwise suitable pipe frame, the coating process will seal such isolated pinholes. A cold-weld metal filler may be a desired application on a small section and wrapped with a fiberglass resign to ensure a sturdy reinforced substrate.
Pipe Cleaning
Internally the system must be thoroughly flushed and drained from all fluid and debris, followed by high velocity air flow to facilitate drying and removal of all moisture.
The pipe surface shall be restored to substrate by sequentially passing a specific airborne abrading agent. The prepared surface preparation standard will be picked based on remaining wall thickness. The prep-surface shall be free of oil, dust. mill scale. oxides and other foreign material.
NACE No. 1/SSPC-SP-5: White Metal Blast Cleaning
NACE No. 2/SSPC-SP-10: Near-White Commercial Blast Cleaning
NACE No. 3/SSPC-SP-6: Commercial Blast Cleaning
Internal pipe coating
The key to AIR VORTEX® is the advanced level of internal atmospheric control over temperature, Moisture, and velocity. Depending on the type of substrate and on the medium transported, the correct polymer is chosen.